Comparison of recruitability of acute respiratory distress syndrome caused by pulmonary and extrapulmonary in pig models

Yumei Wang1, Yanlin Yang1,(), Xiumei Sun1, Yimin Zhou1, Jingran Chen1, Kunming Cheng1, Hongliang Li1, Jianxin. Zhou1   

  1. 1. Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing 100070, China
  • Received:2020-11-17 Online:2021-05-28 Published:2021-08-13
  • Contact: Yanlin Yang

Abstract:

Objective

To compare the recruitability between pulmonary (ARDSp) and extrapulmonary acute respiratory distress syndrome (ARDSexp) using electric impedance tomography (EIT) in pig models.

Methods

Sixteen healthy Bama pigs were randomly divided into ARDSp and ARDSexp group with 8 animals each. ARDSp model was established using alveolar instillation of hydrochloric acid and ARDSexp was injected with oleic acid through atrium venous. After the model was established, the animal received lung protective ventilation. After a recruitment maneuver, low (5 cmH2O) and high (25 cmH2O) PEEP were applied in each animal remaining other setting unchanged for 1 hour. Then an end-inspiratory and end-expiratory occlusion were performed. The recruitment volume (VREC) generated between high and low PEEP was calculated, and the data of oxygenation and hemodynamic were recorded.

Results

Significant difference was found in VREC between ARDSexp and ARDSp models (P=0.003), and VREC was (1572.8±314.9) ml and (1089.9±224.2) ml, respectively. The ratio of arterial partial pressure of oxygen to inspired oxygen fraction (PaO2/FiO2) increased from (214.3±128.6) mmHg to (447.5±96.0) mmHg (P=0.004) with increasing PEEP in ARDSexp. However, PaO2/FiO2 did not change significantly in ARDSp [(173.6±112.0) mmHg vs (178.4±128.2) mmHg, P=0.943].

Conclusion

The recruitability between ARDSp and ARDSexp in pig models is different. Compared with ARDSp, ARDSexp may have better recruitability. Higher PEEP may improve the oxygenation of ARDSexp, while the effect on ARDSp is relatively small.

Key words: Pulmonary acute respiratory distress syndrome, Extrapulmonary acute respiratory distress syndrome, Recruitability, Recruitment volume, Electric impedance tomography