| 1 |
Finfer S, Myburgh J, Bellomo R. Intravenous fluid therapy in critically ill adults [J]. Nat Rev Nephrol, 2018, 14 (9): 541-557.
|
| 2 |
Evans L, Rhodes A, Alhazzani W, et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 [J]. Intensive Care Med, 2021, 47 (11): 1181-1247.
|
| 3 |
Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness [J]. Curr Opin Crit Care, 2015, 21 (5): 388-394.
|
| 4 |
Bruscagnin C, Shi R, Rosalba D, et al. Testing preload responsiveness by the tidal volume challenge assessed by the photoplethysmographic perfusion index [J]. Crit Care, 2024, 28 (1): 305.
|
| 5 |
Muñoz F, Born P, Bruna M, et al. Coexistence of a fluid responsive state and venous congestion signals in critically ill patients: a multicenter observational proof-of-concept study [J]. Crit Care, 2024, 28 (1): 52.
|
| 6 |
Kattan E, Castro R, Miralles-Aguiar F, et al. The emerging concept of fluid tolerance: a position paper [J]. J Crit Care, 2022, 71: 154070.
|
| 7 |
Kattan E, Ospina-Tascón GA, Teboul JL, et al. Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial [J]. Crit Care, 2020, 24 (1): 23.
|
| 8 |
Rola P, Miralles-Aguiar F, Argaiz E, et al. Clinical applications of the venous excess ultrasound (VExUS) score: conceptual review and case series [J]. Ultrasound J, 2021, 13 (1): 32.
|
| 9 |
Acheampong A, Vincent JL. A positive fluid balance is an independent prognostic factor in patients with sepsis [J]. Crit Care, 2015, 19 (1): 251.
|
| 10 |
Boyd JH, Forbes J, Nakada TA, et al. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality [J]. Crit Care Med, 2011, 39 (2): 259-265.
|
| 11 |
Nichol J, Girling F, Jerrard W, et al. Fundamental instability of the small blood vessels and critical closing pressures in vascular beds [J]. Am J Physiol, 1951, 164 (2): 330-344.
|
| 12 |
Monge García MI, Gil Cano A, Gracia Romero M. Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients [J]. Crit Care, 2011, 15 (1): R15.
|
| 13 |
Alvarado-Sánchez JI, Salazar-Ruiz S, Caicedo-Ruiz JD, et al. Predictive value of dynamic arterial elastance for vasopressor withdrawal: a systematic review and meta-analysis [J]. Ann Intensive Care, 2024, 14 (1): 108.
|
| 14 |
García MI, Romero MG, Cano AG, et al. Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study [J]. Crit Care, 2014, 18(6): 626.
|
| 15 |
Ince C. Hemodynamic coherence and the rationale for monitoring the microcirculation [J]. Crit Care, 2015, 19 (Suppl 3): S8.
|
| 16 |
Hernández G, Valenzuela ED, Kattan E, et al. Capillary refill time response to a fluid challenge or a vasopressor test: an observational, proof-of-concept study [J]. Ann Intensive Care, 2024, 14 (1): 49.
|
| 17 |
Chandrasekhar A, Padrós-Valls R, Pallarès-López R, et al. Tissue perfusion pressure enables continuous hemodynamic evaluation and risk prediction in the intensive care unit [J]. Nat Med, 2023, 29 (8): 1998-2006.
|